Power Input:
- 100mA, 24Vdc power supply (Not Included)
- Internal Battery (Setup & totalizer memory storage only)
- 3 V 250mA -H Lithium (2 yr. Standby life)
Display:
Rate Display: (selectable decimal)
- 3.5 or 4.5 Digits (selectable), 0.35" High, display updates once every two seconds.
- Rate Descriptor: /SEC, /MIN, /HR, or Blank
Totalizer Display: (selectable decimal)
- 8 Digit (99999999), 0.2" High
- Totalizer Descriptors: GAL, LIT, FT3, M3 or "blank"
- Low Battery Error Detection: "BAT" descriptor
- Under / Over range Indication: Flashing display
Environmental:
Operating Temperature
- -4ºF (-20ºC) to +158ºF (70ºC)
Humidity
Accuracy:
0.1% Full Scale Resolution, ± 1 Count
Temperature Drift:
- 50 ppm/ºC Typical
- 200 ppm/ºC Worst Case
Listing: CE Compliant |
Inputs:
Signal Inputs:
- Full Scale Range: 4 to 20 mA DC
- Loop Voltage Drop: 6 Volts Maximum
- Reverse Polarity Protection
- Over Current Protection to 60 mA
- 16 Bit resolution; 1 sample every 2 seconds
- Low cutoff supplied to inhibit indications at low flow rates
Reset Inputs:
- Internal Pullup Resistor: 100 kΩ to ± 3 VDC
- High (logic 1): Open or 3-30 VDC
- Low (logic 0): Less than .5 VDC
- Minimum On: 25 msec
Pulse Output:
The pulse output advances with the least significant digit of the totalizer
Type: Opto-isolated open collector transistor
- Max. voltage (off state): 30 VDC
- Current (on state): 5 mA @ .9 V drop, .1 mA @ .7 drop
- Pulse Duration: 15 msec
- Pulse Output Rate: 25 CPS max.
- Pulse output divider: User selectable. ÷ 1, ÷ 10, ÷ 100 or off
Calibration & Operation:
- Input Scaling: Via front keypad
- Decimal Point: Via front keypad
- Reset Input: Via front keypad or remote dry contact closure
- Keypad: 4 tactile feedback keys
|